Hot box test elements - U-values of windows, doors, skylights, industrial doors measured to BS EN ISO 12567 Parts 1 and 2
Windows measured as specified in BS EN ISO 12567-1
(1198 ± 2 mm) x (1198 ± 2 mm) x (maximum thickness 150 mm)
OR
(1478 ± 2 mm high) x (1228 ± 2 mm wid ) x (maximum thickness 300 mm)
Roof windows and skylights as specified in BS EN ISO 12567-2
(1198 ± 2 mm) x (1198 ± 2 mm) x (maximum depth 450 mm)
(1478 ± 2 mm high) x (1228 ± 2 mm wide) x (maximum depth 450 mm)
(1673 ± 2 mm high) x (1418 ± 2 mm wide) x (maximum depth 450 mm)
Residential doors measured as specified in BS EN ISO 12567-1
(1997 ± 3 mm) x (998 ± 2mm) x (maximum thickness 150 mm)
Industrial doors (measured as specified in BS EN 13241 and BS EN 12428)
(1998 ± 2 mm x 1998 ± 2 mm) x special thickness considerations must be discussed
General structures
(1997 ± 3 mm) x (998 ± 2mm) x (maximum thickness 150 mm)
OR
(1478 ± 2 mm high) x (1228 ± 2 mm wide) x (maximum thickness 300 mm)
Heavy structures (> 100 kgs < 500 kg)
(1198 ± 2 mm) x (1198 ± 2 mm) x (maximum thickness 350 mm)
Evaluation of reflective insulation systems
Generally either:
(1478 ± 2 mm high) x (1228 ± 2 mm wide) x (maximum thickness 300 mm)
OR
(1997 ± 3 mm) x (998 ± 2mm) x (maximum thickness 150 mm)
See separate page for more details
Special sizes
Outside of the sizes given above specimens of any size up to 2 m x 2 m can be accommodated at extra cost.